Product Available Now

1200A Switchboard

UL 891 listed enclosed switchboard, suitable for use as service equipment. 480Y/277 VAC, 3-phase, 65 kA SCCR, with twelve 125A molded-case branch breakers on bolted dead-front construction.

Best Suited For: Utility Service Entrance UPS / PDU Feed

P/N: BS1200x12D100_UL891_M1  ·  UL File: E529270  ·  Rev. 1.0 (2026)

Service Rating1,200 A
SCCR65 kA @ 480V
ListingUL 891
BITSINK 1200A switchboard

UL 891 listed service equipment

Suitable for use as service equipment under UL File E529270.

Integral Arc Reduction Maintenance System

Main breaker's ARMS function lowers incident energy during live maintenance.

Residual ground fault protection

Integral GFP per NEC 230.95 with LSIG trip functions on the main device.

Active thermal management

Filtered forced-air cooling with adjustable thermostat, 40°C activation setpoint.

Bolted dead-front construction

No hinged doors — bolted covers per UL 891 switchboard convention.

Factory documentation package

BOM, single-line, layout drawings, GFP test instructions, and FAT report included.

General Specifications
Equipment TypeEnclosed Switchboard — Service Equipment
ListingUL 891 Listed — Suitable for Use as Service Equipment
UL FileE529270 (BITSINK LLC)
Supply Voltage480Y/277 VAC, 3-phase, 4-wire + ground, solidly grounded wye, 60 Hz
Service Rating1,200 A
Max Combined Continuous Load960 A
SCCR65 kA RMS symmetrical @ 480 VAC
Enclosure TypeUL / NEMA Type 1 — indoor, general purpose
Service Disconnect & Main OCPD
DeviceNoark M6N1200E3, 3-pole MCCB
Frame / Interrupting Rating1,200 A frame, 600 VAC max, 65 kA @ 480 VAC
Trip UnitLSIG (long-time/short-time/instantaneous/ground fault)
Arc ReductionIntegral Arc Reduction Maintenance System (ARMS)
Ground Fault ProtectionIntegral residual GFP per NEC 230.95
Bus, Neutral & Grounding
Main Power Bus1/4 in × 5 in silver-plated copper, 3-phase
Neutral Disconnect Link1,250 A, installed — isolates neutral for insulation testing
Main Bonding Jumper1/4 in × 5 in silver-plated copper, dedicated per NEC 250.28
Equipment Ground Bus1/4 in × 2 in copper, UL-listed, rated for 100 kA short-circuit withstand
480 VAC Branch Circuits
Branch Devices12 × Noark M2H125T3L, 125 A, 3-pole MCCB, 100 kA @ 480V
Combined Continuous LoadLimited to 950 A; branch positions expandable within bus capacity
Active Thermal Management
System TypeActive forced-air, filtered intake/exhaust
Cooling Fans(4) × 39 CFM, 120 VAC, axial
ControlAdjustable thermostat, 0–60°C range, 40°C activation setpoint
Enclosure Construction
Type RatingUL / NEMA Type 1 — indoor, general purpose
Front AccessMarked per NEC 230.66
Cover BondingBolted dead-front covers (no hinged doors)
Standards & Markings
Equipment StandardUL 891 — Switchboards
Field MarkingAvailable fault current label per NEC 110.24; arc-flash label per NFPA 70E
Branch Breaker StandardUL 489 listed molded-case circuit breakers
DocumentationBOM, single-line, layout drawings, GFP test instructions, FAT report

Switchboard submittals are issued directly by our electrical engineering team after a brief project qualification call.

24/7 Field Service

NETA-certified field engineers for commissioning, testing, and GFP performance testing.

Warranty

Warranty terms available on request from applications engineering.

Spare Parts

Branch breakers and main device components stocked regionally.

Contact Support

Have a load schedule to review?

Send us your one-line and load schedule — our electrical engineers will return a proposed submittal within a week.